Reduction of Earthquake Response of Steel Framed Buildings by FVDs

Author : Krishnapriya V.V. 1 Thahzin Sageer 2

Date of Publication :20th June 2019

Abstract: In this paper an advanced application of fluid viscous damper is investigated. This study investigated whether fluid viscous damper is an alternative for base isolators. The non linear time history analysis result clearly indicates that the use of fluid viscous damper in midrise steel buildings will reduce the earthquake response and is an efficient seismic retrofitting method.

Reference :

    1. A. Hwang (1998) Viscous Dampers : Practical Application Issues for the Structural Engineer, M. E. thesis, Dept. Civil Engineering, Massachusetts Institute of Technology
    2. A.N Sigaher and M. C. Constantinou (2003) ScissorJack-Damper Energy Dissipation, Earthquake Spectra, vol. 19, no. 1, pp. 133-158
    3. Avinash A. R. (2012) Seismic Retrofitting of Structures With Fluid Viscous Dampers – An Analytical Study, M. Tech thesis, Dept. Civil Engineering, Manipal Institute Of Technology
    4. Douglas Taylor and Philippe Duflot (2011) Fluid Viscous Dampers Used For Seismic Energy Dissipation In Structures, Taylor Devices Inc, 90 Taylor drive, North Tonawanda, NY 14120-0748, USA
    5. Eurocode (EC3 [BS EN 1993 -1 -1, 2005], EC8 [BS EN 1998 -1, 2004])
    6. G. Terenzi (1999) Dynamics of SDOF Systems with Nonlinear Viscous Damping, Journal of Engineering Mechanics, vol. 125, no. 8, pp. 956-963
    7. G. Oliveto and M. Marletta (2005) Seismic Retrofitting of Reinforced Concrete Buildings using Traditional and Innovative Techniques, ISET Journal of Earthquake Technology, vol. 42, no. 454, pp. 21-46
    8. Gregg Haskell and David Lee (2013) Fluid Viscous Damping as an Alternative to Base Isolation, Taylor Devices , Inc, Hawn Engineering, California
    9. J.shin Hwang, Y.nan Huang, and Y.hui Hung (2004) Analytical and Experimental Study of Toggle-Brace-Damper Systems, Journal of Structural Engineering, pp. 1035-1043
    10.  Japan Building Disaster Prevention Association (2005) Recent Development of Seismic Retrofit Methods in Japan, A Technical report
    11.  J.shin Hwang, S.jung Wang, Y.nan Huang, and C.hsiang Tsai (2006) Experimental Study of a RC Structure with Toggle-Brace-Dampers, 4th International Conference on Earthquake Engineering, no. 204, pp. 1-9 64
    12.  J. P. Ou, X. Long, and Q. S. Li (2007) 12. Seismic response analysis of structures with velocitydependent dampers, Journal of Constructional Steel Research, vol. 63, pp. 628-638
    13. Jinkoo Kim, Seungjun Lee and Hyunhoon Choi (2011) Progressive collapse resisting capacity of moment frames with viscous dampers, The Structural Design of Tall and Special Buildings, Wiley Online Library, DOI: 10.1002/tal.692